Global commands
2.1 Global commands
Command
VA<CR>
Description
- Returns the firmware version.
- Return Syntax: OK + Vx.xxxx + <CR>
- x indicates numbers for a firmware version
Example
If the returned value is OKV1.00<CR>, current firmware version is 1.00.
Command
MO<CR>
Description
- Returns current status mode in CS-CAN.
- Return Syntax: OK + x + <CR>
- x should be a number ‘0’ or ‘1’. (1: Active, 0:Configuration)
Example
If the returned value is OK1<CR>, current status mode is Active mode.
Command
RC<CR>
Description
- Reads CAN communication settings in CS-CAN.
- Return Syntax: OK+RC+(BS)+<CR>
- B Baud rate
0: 83kbps 1: 100kbps 2: 125kbps
3: 250kbps 4: 500kbps 5: 1000kbps
- S CAN Spec.
A: CAN 2.0 A B: CAN 2.0 B
Example
If the returned value is OKRC2B<CR>, current Baud rate is 125bps and it is
working with CAN 2.0 B Spec.